• Eye exam with indirect ophthalmoscopy for diagnosis of disseminated tuberculosis in patients with HIV/AIDS

      Heiden, David; Margolis, Todd P; Lowinger, Alan; Saranchuk, Peter (BMJ Publishing Group, 2013-05-01)
    • The kynurenine pathway of tryptophan catabolism, CD4+ T-cell recovery, and mortality among HIV-infected Ugandans initiating antiretroviral therapy.

      Byakwaga, Helen; Boum, Yap; Huang, Yong; Muzoora, Conrad; Kembabazi, Annet; Weiser, Sheri D; Bennett, John; Cao, Huyen; Haberer, Jessica E; Deeks, Steven G; et al. (Oxford University Press, 2014-08-01)
      Human immunodeficiency virus (HIV) infection-induced indoleamine 2,3-dioxygenase-1 (IDO) expression in activated monocytes and dendritic cells catabolizes tryptophan to kynurenine and other downstream catabolites that inhibit T-cell proliferation and interleukin 17 (IL-17) production. The prognostic significance of this pathway in treated HIV disease is unknown.
    • The Partec CyFlow Counter could provide an option for CD4+ T-cell monitoring in the context of scaling-up antiretroviral treatment at the district level in Malawi.

      Fryland, M; Chaillet, P; Zachariah, R; Barnaba, A; Bonte, L; Andereassen, R; Charrondière, S; Teck, R; Didakus, O; Médecins sans Frontières-Luxembourg, Thyolo District, Malawi. (Elsevier, 2006-10)
      A study was conducted in rural Malawi to verify (a) whether the Partec CyFlow Counter((R)) for CD4+ T-cell lymphocyte counting in HIV-positive individuals could be introduced into a district hospital laboratory and (b) whether it would produce CD4 counts of acceptable quality. CD4+ cell counting was performed using the Partec CyFlow Counter and the results were compared with a reference method (FACsCount). A total of 311 blood samples were analysed and the correlation coefficient for the CyFlow Counter was 0.92 (95% CI 0.89-0.95). Mean CD4 counts using the Partec and the reference methods were 308.2 cells/microl and 316.9 cells/microl, respectively. The mean difference in CD4 count values was -8.68 cells/microl (95% CI -18.8 to 1.4). Mean intra-run variation was -6.84 cells/microl (95% CI -12.9 to 0.79). In the district laboratory setting, the instrument could accommodate up to 75 blood samples per technician per day. After being trained, local laboratory staff found the CyFlow Counter procedures simple to run and the instrument easy to manipulate. The Partec CyFlow Counter produces sufficiently reliable results and the instrument appears robust under field conditions. It could provide a new option for introducing routine CD4+ cell monitoring at the district level in the context of scaling-up antiretroviral therapy in Malawi.
    • Viral Load Versus CD4⁺ Monitoring and 5-Year Outcomes of Antiretroviral Therapy in HIV-Positive Children in Southern Africa: a Cohort-Based Modelling Study

      Salazar-Vizcaya, L; Keiser, O; Karl, T; Davies, MA; Haas, Andreas D; Blaser, N; Cox, V; Eley, B; Rabie, H; Moultrie, H; et al. (Lippincott Williams & Wilkins, 2014-10-23)
      Many paediatric antiretroviral therapy (ART) programmes in Southern Africa rely on CD4⁺ to monitor ART. We assessed the benefit of replacing CD4⁺ by viral load monitoring.