Prospective Evaluation of the Diagnostic Accuracy of Dried Blood Spots from Finger-Prick for the Determination of HIV-1 Viral Load with the NucliSENS Easy-Q HIV-1 v2.0 in Malawi
Authors
Fajardo, EmmanuelMetcalf, Carol A
Chaillet, Pascale
Aleixo, Lucia
Pannus, Pieter
Panunzi, Isabella
Triviño, Laura
Ellman, Tom
Likaka, Andrew
Mwenda, Reuben
Issue Date
2014-02-05
Metadata
Show full item recordJournal
Journal of Clinical MicrobiologyAbstract
HIV-1 viral load (VL) testing is not widely available in resource-limited settings. Use of finger-prick dried blood spot (FP-DBS) samples could remove barriers related to sample collection and transport. Measurement of VL using DBS from EDTA venous blood (VB-DBS) in place of plasma has previously been validated using the NucliSENS EasyQ HIV-1 v2.0 assay, but information on the accuracy of FP-DBS samples for measuring VL is limited. This prospective study, conducted at Thyolo District Hospital in Southern Malawi, compared VL levels measured on FP-DBS samples and plasma, using the NucliSENS EasyQ HIV-1 v2.0 assay. Comparability was assessed by means of agreement and correlation (131 patients with VLs ≥100 copies/ml), and sensitivity and specificity (612 patients on ART). Samples of EDTA venous blood and FP-DBS from 1,009 HIV-infected individuals were collected and prepared in the laboratory. Bland-Altman analysis found good agreement between plasma and FP-DBS VL levels, with a mean difference of -0.35 log10, and 95% limits of agreement from -1.26 to 0.55 log10. FP-DBS had a sensitivity of 88.7% (95% confidence interval [CI]: 81.1 - 94.4%) and specificity of 97.8% (95% CI: 96.1 - 98.9%) using a 1,000 copies/ml cut-point; and a sensitivity of 83.0% (95% CI: 73.4 - 90.1%) and specificity of 100% (95% CI: 99.3-100%) using a 5,000 copies/ml cut-point. This study shows that FP-DBS is an acceptable alternative to plasma for measuring VL using the NucliSENS EasyQ HIV-1 v2.0. We are conducting a second study to assess the proficiency of health workers at preparing FP-DBS in primary healthcare clinics.Publisher
American Society for MicrobiologyPubMed ID
24501032Language
enISSN
1098-660Xae974a485f413a2113503eed53cd6c53
10.1128/JCM.03519-13
Scopus Count
Collections
Related articles
- Finger Prick Dried Blood Spots for HIV Viral Load Measurement in Field Conditions in Zimbabwe.
- Authors: Napierala Mavedzenge S, Davey C, Chirenje T, Mushati P, Mtetwa S, Dirawo J, Mudenge B, Phillips A, Cowan FM
- Issue date: 2015
- Dried blood spot HIV-1 RNA quantification: a useful tool for viral load monitoring among HIV-infected individuals in India.
- Authors: Neogi U, Gupta S, Rodridges R, Sahoo PN, Rao SD, Rewari BB, Shastri S, Costa AD, Shet A
- Issue date: 2012 Dec
- Measures of viral load using Abbott RealTime HIV-1 Assay on venous and fingerstick dried blood spots from provider-collected specimens in Malawian District Hospitals.
- Authors: Rutstein SE, Kamwendo D, Lugali L, Thengolose I, Tegha G, Fiscus SA, Nelson JA, Hosseinipour MC, Sarr A, Gupta S, Chimbwandira F, Mwenda R, Mataya R
- Issue date: 2014 Aug
- Field evaluation of dried blood spots for routine HIV-1 viral load and drug resistance monitoring in patients receiving antiretroviral therapy in Africa and Asia.
- Authors: Monleau M, Aghokeng AF, Eymard-Duvernay S, Dagnra A, Kania D, Ngo-Giang-Huong N, Touré-Kane C, Truong LX, Chaix ML, Delaporte E, Ayouba A, Peeters M, ANRS 12235 Study Group.
- Issue date: 2014 Feb
- HIV-1 viral load measurement in venous blood and fingerprick blood using Abbott RealTime HIV-1 DBS assay.
- Authors: Tang N, Pahalawatta V, Frank A, Bagley Z, Viana R, Lampinen J, Leckie G, Huang S, Abravaya K, Wallis CL
- Issue date: 2017 Jul